DLR Portal
Home|Imprint|Sitemap|Contact |Deutsch
You are here: Home:Research:Hands
Advanced Search
Robotics and Mechatronics Center
Institute of Robotics and Mechatronics
Institute of System Dynamics and Control
Institute for Optical Sensor Systems
News
Staff
Research
Rollin' Justin
Hand Arm System
Light-Weight Robots
Hands
Images
Legged Robots
3D Modeller
Medical Robotics
Mechatronic devices
Biomimetic Robotics and Machine Learning
Telepresence & VR
Vision
Space Robotics
Flying Robots
Demonstrators
Flugzeug-Systemdynamik
Automotive
Railway Systems
Control Methods & Tools
Industrial Robot Control
Multikopter
Ausgründungen
Publications
Job offers
Downloadable Images
How to get to us
Kooperationen und Projekte
Back
Send article to a friendPrint

Data sheet of DLR Hand II



Sensors of a single finger

  • 3 joint position sensors: specially designed conductive plastic potentiometers
  • 3 joint torque sensors: strain gauge sensors
  • 3 motor position/speed sensors: analog Hall sensors with interpolation
  • 1 six-dimensional finger tip force torque sensor: strain gauge sensors
  • 3 motor temperature sensors: NTCs
  • 3 sensors for temperature compensation: integrated sensors


Actuators

Brushless DC motor with Harmonic-Drive and tooth belt gear

Motors: 11(24) mNm, 17,000 rpm for medial joint
24(35) mNm, 6,000 rpm for proximal joint
Gears: Harmonic Drive gears, 1.8 Nm, 6,000 rpm, 100:1 identical for all joints
Tooth belt gear: 1.2:1 in proximal joint
2:1 in medial joint

Degrees of Freedom

  • Four identical fingers with four joints and three degrees of freedom the medial and distal joints are directly coupled 1:1. One additional degree of freedom in the palm. In total the hand has 13 degrees of freedom.

Mechanics

  • Four identical fingers with four joints and three degrees of freedom each and an aluminum open skeleton structure with injection molded plastic shells
  • bevel gear in the base joint

Motion ranges

extension / flexion proximal joint - 55° / 75°
abduction / adduction proximal joint ± 37°
extension / flexion medial and distal joint - 20° / 105°

Link lengths

proximal link 75 mm
medial link 40 mm
distal link 40 mm

Forces/Torques

active force perpendicular to the stretched fingertip: 30 N

Speed

approximately 360°/s for each joint

Weight

a single finger: 375 g
the complete hand: 1800 g

Electronics

  • Sensor electronics located directly beside the sensors
  • A/D-conversion in each finger link. Serial communication system connecting within the finger to connect the finger links with a minimum number of cables. Serial communication system connecting the fingers to the hand and the hand to any external control computer.
  • Number of cables to the hand:
    • 4-wire power supply (24 V motor power supply and 50 V, 20 kHz power supply for electronics)
    • 8-wire serial communication interface
  • Hot pluggable tool change within a few seconds with a customized tool retainer

Control computer

Two-CPU PowerPC VME bus system